Chenbro Storage Server Chassis with 4-Drive Mini-SAS Backplane (80H103215-013 with LED module 80H033215-005 VER:A2) for RM11704B, RM12404B, RM21508B, RM31212B, and RM41416B

Please read the general information in this section before selecting the specific chassis from the compatibility matrix below. Click on the Chassis number to open a page with details about that specific configuration.

 

Compatible Chassis, Controllers, and Cables

Chassis

RAID Controller

# of Drives

SAS

SATA

Number and Chenbro part code for cables

RM11704B

3405

4

x

x

1 x 26H113215-012

RM12404B

3405

4

x

x

1 x 26H113215-012

RM21508B

3805

8

x

x

2 x 26H113215-012

RM31212B

31205

12

 

x

3 x 26H113215-012

RM41416B

31605

16

 

x

4 x 26H113215-012

 

Connector Details

 

CN1: Mini-SAS connector to Host

CN4: Backplane ID setting jumper

CN5: Fan failure/HDD access LED output connector (to LED board)

 

Jumper Settings

CN4 sets the backplane ID (see illustration below). Each backplane must have a unique ID number and the backplane physically nearest the bottom of the system must have ID #1.

 

Pin         CN4 Backplane ID

1-2

#1

3-4

#2

5-6

#3

7-8

#4

9-10

#5

11-12

#6

 

LED Module

For configurations using the LED module (part 80H033215-005 VER:A2):

  1. Connect the daisy chain cable to CN5 on each backplane and then to CN2 on the LED module itself.

  2. Ensure that the jumper switch setting on the LED module is set to the defaults as indicated by ** in the table below.

SW-1:
DIP1 - DIP4

Function

ON

OFF

1

Monitoring BP Fan Q'ty Setting

5

4**

2

Monitoring Temperature Setting

65° C

55° C**

3

SATA HDD Spin Up

Simultaneously ON

Sequential Spin Up**

4

Fan Alarm Setting

Enable**

Disable

 

SW1:
DIP5 - DIP6

Function

Dip5

Dip6

 

For 1U RM11704B

OFF

OFF

 

For 2U RM21508B

ON

OFF

 

For 3U RM31212B

OFF

ON

 

For 4U RM41416B

ON

ON

 

Disk Carrier LEDs

The Chenbro 4-drive mini-SAS backplane for RM series includes an SGPIO processor device which manages the backplane LEDs. The RAID controller communicates with the SGPIO device using dedicated signals within the mini-SAS link cable.

Note: Ensure you use a mini-SAS to mini-SAS link cable type which connects the sidebands signals.

Activity LED

Drive fault condition

Identify drive (Adaptec Storage Manager)

Adaptec Storage Manager

Adaptec Storage Manager will display each 4-slot mini-SAS backplane as a separate enclosure and will report an Adaptec SGPIO SEP device corresponding to the Chenbro enclosure processor device.

Note: Adaptec Storage Manager displays the first disk slot on the first backplane as “slot 0”.