ICP Controller Firmware Upgrade Kit
===================================
 
You will need:
One DOS bootable formatted 3.5", 1.44BM floppy disk
One formatted 3.5", 1.44MB floppy disk
 
 
Copy the following files to the 1.44MB DOS floppy disk:
   GDTX000.EXE    
   GDTSETUP.EXE or ICPCON.EXE
   GDT_RPFW.???   the firmware file (??? = version of the firmware)
 
1) Boot the system to MS-DOS 
 
2) Remove the bootable disk and place the disk containing the ICP files in 
   the floppy drive.
 
3) Load the MS-DOS driver (GDTX000 "Enter")
 
4) Start GDTSETUP or ICPCON, select the Controller, change with "F4" to the
   "Advanced Setup", select "Configure Controller" and then "Firmware Update"
   type the drive letter where the update disk is located (e.g. A:)
 
5) Select the path of the new firmware library GDT_RPFW.* or simply enter
   "." for the current directory. Select the firmware file by
    pressing Enter and follow the instructions of GDTSETUP / ICPCON.
 
*** DO NOT TURN OFF POWER OR RESET THE SYSTEM DURING FW UPDATE !!! ***
 
6) After the firmware update is completed you will be returned to the
   Configure Controller menue.
   Press "Esc" three times to exit. Press "Y" to quit.
   A message appears informing you that a firmware update has been detected.
   Remove the floppy disk and press "Enter" to reboot the system.
 
7) The operating system drivers and tools should be updated as well.
 
 